Top Tips Of Refresh 1Z0-632 Exam Price
Proper study guides for Updated Oracle PeopleSoft PeopleTools 8.5x Implementation Essentials certified begins with Oracle 1Z0-632 preparation products which designed to deliver the Verified 1Z0-632 questions by making you pass the 1Z0-632 test at your first time. Try the free 1Z0-632 demo right now.
Also have 1Z0-632 free dumps questions for you:
NEW QUESTION 1
Which statement is correct about the following PeopleCode statement?
- A. RO_ROWSET is the superclass of the Rowset class
- B. Rowset is the superclass of the RO_ROWSET class
- C. RO_ROWSET is an instance of the Rowset class
- D. Rowset is a subclass of the RO_ROWSET class
- E. RO_ROWSET is an application class in the Rowset application package
Answer: D
NEW QUESTION 2
In this exhibit, identify two settings on the Internet tab of the Component Properties dialog box that apply to fluid components. (Choose two.)
- A. In the Search Page group box: Primary Action
- B. In the Search Page group box: Instructional Text
- C. In the Pagebar group box: Help Link
- D. In the Toolbar group box: Notify
- E. In the Toolbar group box: Save
- F. In the Multi-Page Navigation group box: Display Folder Tabs (top)
Answer: AF
NEW QUESTION 3
Examine this PeopleCode statement:
&Date = ORDER.DATE;
Select the object-oriented equivalent.
- A. Option A
- B. Option B
- C. Option C
- D. Option D
- E. Option E
Answer: A
NEW QUESTION 4
You are asked to modify the Customer Products Purchased application to provide auto complete on the search page for the customer name. This application uses the following definitions.
How will you implement this change?
- A. Select the Enable Autocomplete when used in Search Record check box for the DESCR field on the PSU_ CUST_PROD record
- B. Select the Enable Autocomplete when used in Search Record check box for the CUSTOMER_ID field on the PSU_ CUST_PROD record
- C. Select the Force Search Processing check box on the Use tab of the Component Properties dialog box for PSU_CUST_PROD
- D. Select the Enable Autocomplete when used in Search Record check box for the DESCR field on the PSU_ CUST_TBL record
- E. Select the Enable Autocomplete when used in Search Record check box for the CUSTOMER_ID field on the PSU_CUST_TBL record
- F. Select the Show Prompt Button check box for the DESCR field on the PSU_CUST_PROD page
Answer: C
NEW QUESTION 5
View the following sample search page:
On the Human Capital Management search page, why is the Course Code field limited to accept only “begins with” searches, whereas the Description field accepts a wide range of search operators?
- A. Description is an alternate search key
- B. The Required check box is selected for the Course Code field on the Edits tab of the Record Field Properties dialog box
- C. Course is a character (Char) field, while Description is a long character (Long) field
- D. Disable Advanced Search Options is selected for the Course field on the Use tab of the Record Field Properties dialog box
- E. Course is a primary key, and primary keys can only run “begins with” searches
Answer: D
NEW QUESTION 6
When you attempt to drag a subrecord onto a page, the page definition displays an error. What is the reason for this?
- A. The Use tab on the Page Properties dialog box does not have the Page Size field set to Auto-size so that the page automatically expands to facilitate all the fields in the subrecord
- B. The subrecord definition does not have the Record Type value set to SubRecord
- C. The Use tab on the Record Properties dialog box for the subrecord definition does not have the Parent record field set correctly in the Record Relationship settings
- D. The Page Type Field is not set to be Subpage on the Use tab of the Page Properties dialog box
Answer: C
NEW QUESTION 7
At what occurs level is the Reviewer Details scroll area?
Answer: A
NEW QUESTION 8
You begin to register a component using the Registration Wizard. What should you do based on the values that appear in the dialog box?
- A. Select the Always use default local node? Check box and then continue the registration
- B. Continue registering the component as is
- C. Stop the registration process to investigate why this component is already registered
- D. Change the user-facing fields to mixed case and make them less technical, and then continue registering the component
Answer: B
NEW QUESTION 9
An end user is accessing your field application for the first time using her smartphone. What will the end user notice based on the settings shown in this example?
- A. The end user will not be able to navigate back to pages previously accessed
- B. The end user will need to navigate to the classic homepage to access this component because it is an activity guide
- C. To save screen space on the small screen and to send less data to the phone, only the layout outline of the page elements will be visible
- D. The Notifications button will not appear in the fluid header for smartphones
- E. The end user will not see a tile on the fluid homepage to tap for accessing for the component
Answer: A
NEW QUESTION 10
If you were to create a page displaying information from each of the tables listed in the exhibit, at what occurs level would the fields of the PSU_EMP_RVW_FCT table be on?
Answer: D
NEW QUESTION 11
Your client has asked you to update their PeopleCode programs to replace outdated system variables with current system variables. Which system variable replaces %OperatorId?
- A. %Session
- B. %CurrentUser
- C. %UserId
- D. %SessionUser
- E. %SessionId
- F. %SignonUserId
Answer: C
NEW QUESTION 12
You are asked to create a new field definition with a field label that includes a line break for Curriculum Developer. How should you enter the label?
- A. Curriculum/Developer
- B. Curriculum\Developer
- C. Curriculum/nDeveloper
- D. Curriculum<br>Developer
- E. Curriculum\nDeveloper
Answer: D
NEW QUESTION 13
Which two PeopleCode excerpts contain syntax errors? (Choose two.)
Answer: DE
NEW QUESTION 14
When testing a fluid page, one of your colleagues says that the page suddenly is not rendering as expected. He believes he may have accidentally deleted a group box on the page. Using the developer tools of your browser, you inspect the HTML elements.
Which vital structural element of a fluid page must still exist in order for the page to render properly?
- A. <div class=”ps_anchor”… .</div>
- B. <div class=”ps_main”… .</div>
- C. <div class=”ps_box-pagetabs”… .</div>
- D. <div class=”ps_pspagecontainer_srch” … .</div>
- E. <div class=”ps_box-group psc_layout psc_apps_content”… .</div>
Answer: E
NEW QUESTION 15
At line number 7 in this record definition, the PSU_ADDRESS_XXX field name represents a .
- A. Subpage
- B. Compound field
- C. Subrecord
- D. Derived/Work record
- E. Composite field
Answer: C
NEW QUESTION 16
You receive the following memo:
We need a new field to store skills. At the present time, we have identified five skills; however, this will likely increase in the future. Each skill will have a three-character code and a description. We want the skill to be searchable by the description.
How would you create this field?
- A. Create a three-character field for SKILL and add translate values for the initial five skills define
- B. When you add the field to the record, set it up as an alternate search key and translate table edit
- C. Create a three-character field for SKILL and then create a Skills table with two fields: SKILL and DESC
- D. When you add the field to the record, set it up as a prompt table edit referencing the Skills table
- E. Create a three-character field for SKILL and then create a Skills table with two fields: SKILL and DESC
- F. When you add the field to the record, set it up as an alternate search key and prompt table edit referencing the Skills table
- G. Create a three-character field for SKILL and add translate values for the initial five skills define
- H. Whenyou add the field to the record, set it up as a translate table edit
Answer: D
NEW QUESTION 17
You created a new component and registered it in the portal registry. However, when you test it, the content reference is not shown in the menu navigation.
To troubleshoot this issue, examine .
- A. the component structure
- B. the portal registry for component parameters
- C. the portal registry for content reference security
- D. the menu definition for the associated component
- E. the component definition for assigned actions
Answer: D
NEW QUESTION 18
What do you need to do to display the Add a New Value search page as shown in this exhibit?
- A. Select the Add check box in the Toolbar group box on the Internet tab of the Component Properties dialog box
- B. Select a Primary Action of New in the Search Page group box on the Internet tab of the Component Properties dialog box
- C. Select a Default Search Action of Add in the Search Page group box on the Internet tab of the Component Properties dialog box
- D. Select the Add check box in the Actions group box on the Use tab of the Component Properties dialog box.
- E. Select a record from the Add search record drop-down list on the Use tab of the Component Properties dialog box
Answer: B
NEW QUESTION 19
Which two statements indicate the actions that need to be taken before changing the default field label on a field definition? (Choose two.)
- A. Check if the default label is used in any page definitions
- B. Check if the default label is used in any record definitions
- C. Check if the default label is used in any component definitions
- D. Check if the default label is used in any PeopleCode
- E. Check if the default label is active
Answer: AB
NEW QUESTION 20
You are testing the new Customer Table page and notice that you are missing a Return to Search button on the page.
To add this button in Application Designer, open the Component Properties dialog box and .
- A. On the Internet tab, select Return to Search
- B. On the Internet tab, select Page Navigation in History
- C. On the Use tab, select Update/Display
- D. On the Internet tab, select Return to List
- E. On the Use tab, select Return to Search
Answer: D
NEW QUESTION 21
You click a value on the search page and get a SQL error as shown in this exhibit.
What should you do to troubleshoot this issue and fix it?
- A. Check the page definition, make the necessary changes, and save the page
- B. Check the Use tab of the Component Properties dialog box, verify the search record, make the necessary changes, and save the component
- C. Check if the record definition was modified by another developer and perform an alter table
- D. Check the record key structure, make the necessary changes, save the record, and then perform a create indexes
- E. Check the record key, alternate search key, and list box settings of the search record, and save the record
Answer: A
NEW QUESTION 22
A colleague needs to update a custom cascading style sheet (CSS) style for your team’s fluid application. She has the style definition shown in this exhibit open in Application Designer, but isn’t sure if she has opened the correct style definition and asks for your advice.
How do you know she does not have a fluid CSS style open?
- A. The fluid user interface does not use the Arial or the sans-serif font
- B. The fluid user interface uses only the Lucida Grande and Helvetica Neue fonts
- C. In the fluid user interface, font color is not set on the style definitio
- D. The current branding theme is what determines the font color for the fluid user interface display
- E. The fluid user interface does not use absolute font size
- F. Only relative font sizes apply to the dynamic nature of the fluid user interface
- G. The fluid user interface uses only free form style sheets, and this style sheet is a fixed from style sheet
- H. Fluid style sheets all have _FL appended to the style name
Answer: D
Recommend!! Get the Full 1Z0-632 dumps in VCE and PDF From Dumpscollection.com, Welcome to Download: https://www.dumpscollection.net/dumps/1Z0-632/ (New 80 Q&As Version)