getcertified4sure.com

Tested 2V0-622 Study Guides 2021




Want to know features? Want to lear more about experience? Study . Gat a success with an absolute guarantee to pass VMware 2V0-622 (VMware Certified Professional 6.5 - Data Center Virtualization) test on your first attempt.

Online VMware 2V0-622 free dumps demo Below:

NEW QUESTION 1
What is the maximum supporter number of vCPU per VM in VMware vSphere 6.5?

  • A. 246
  • B. 128
  • C. 64
  • D. 32

Answer: B

Explanation: https://www.vmware.com/pdf/vsphere6/r65/vsphere-65-configuration-maximums.pdf

NEW QUESTION 2
Which three object types can be stored in the Content Library? (Choose three.)

  • A. vDS backups
  • B. VM templates
  • C. vAPP templates
  • D. ISO files

Answer: BCD

NEW QUESTION 3
An administrator sets the Failover Capacity for both CPU and Memory at 25%. Based on the Exhibit below, how much of the cluster's total CPU resources are still available to power on additional virtual machines?
2V0-622 dumps exhibit

  • A. 45%
  • B. 60%
  • C. 70%
  • D. 25%

Answer: A

Explanation: The way that Current Failover Capacity is calculated and used with this admission control policy is shown with an example. Make the following assumptions about a cluster: The cluster is comprised of three hosts, each with a different amount of available CPU and memory resources. The first host (H1) has 9GHz of available CPU resources and 9GB of available memory, while Host 2 (H2) has 9GHz and 6GB and Host 3 (H3) has 6GHz and 6GB. There are five powered-on virtual machines in the cluster with differing CPU and memory requirements. VM1 needs 2GHz of CPU resources and 1GB of memory, while VM2 needs 2GHz and 1GB, VM3 needs 1GHz and 2GB, VM4 needs 1GHz and 1GB, and VM5 needs 1GHz and 1GB. The Configured Failover Capacity is set to 25%.Admission Control Example with Percentage of Cluster Resources Reserved Policy
The total resource requirements for the powered-on virtual machines is 7GHz and 6GB. The total host
resources available for virtual machines is 24GHz and 21GB. Based on this, the Current CPU Failover Capacity is 70% ((24GHz – 7GHz)/24GHz). Similarly, the Current Memory Failover Capacity is 71% ((21GB-6GB)/21GB).Because the cluster’s Configured Failover Capacity is set to 25%, 45% of the cluster’s total CPU resources and 46% of the cluster’s memory resources are still available to power on additional virtual machines.

NEW QUESTION 4
Which is required for configuring iSCSI Software Adapter network port binding?

  • A. VMkernel of the iSCSI traffic must be load balanced using Route based on IP Hash algorithm.
  • B. VMkernel of the iSCSI traffic must be load balanced using Route based on Source Virtual Port ID algorithm.
  • C. VMkernel of the iSCSI traffic must be load balanced using Route based on Source MAC Hash algorithm.
  • D. VMkernel of the iSCSI traffic must be bound to only one active network adapter.

Answer: D

NEW QUESTION 5
What advanced parameter defines a custom isolation IP address for a vSphere HA cluster?

  • A. das.isolationaddress
  • B. das.usedefaultisolationaddress
  • C. das.isolationshutdowntimeout
  • D. fdm.isolationpolicydelaysec

Answer: A

NEW QUESTION 6
The Health Check feature in the vSphere Distributed Switch helps troubleshoot network connectivity. What three checks does this feature perform? (Choose three.)

  • A. Network Utilization
  • B. MTU
  • C. VLAN
  • D. Teaming and Failover

Answer: BCD

Explanation: https://kb.vmware.com/s/article/2032878

NEW QUESTION 7
Assuming a mirrored (RAID-1) object configuration, how may hosts must contribute storage in a non-stretched VMware vSAN cluster to satisfy the “Number of failures to tolerate” policy option?
“n” is the desired “Number of failures to tolerate” value for all options.

  • A. 3n
  • B. 2n
  • C. 2n+1
  • D. 2n+2

Answer: C

Explanation: 2V0-622 dumps exhibit

NEW QUESTION 8
Which two components are necessary for the first boot of a host using Auto Deploy? (Choose two.)

  • A. Host Profiles
  • B. Bulk licensing
  • C. vSphere Authentication Proxy
  • D. TFTP
  • E. DHCP

Answer: DE

NEW QUESTION 9
A vSphere Administrator has VM Component Protection (VMCP) enabled, but the VM was not restarted when one of the VMFS datastores experienced an All Paths Down (APD) failure.
What two scenarios would explain why the virtual machine was not restarted? (Choose two.)

  • A. Insufficient Capacity is available on the failover ESXi hosts.
  • B. VM Monitoring is required in order for VMCP to failover during an APD event.
  • C. VMware Tools is not installed on the guest operating system for the VM.
  • D. The APD failure was corrected before the VM could be restarted.

Answer: AD

NEW QUESTION 10
In vCenter Server 6.5, Host Customizations within Host Profiles be exported as which two formats? (Choose two.)

  • A. .xlsx
  • B. .csv
  • C. .ova
  • D. .xls
  • E. .vpf

Answer: BE

NEW QUESTION 11
An administrator notices that a host is evacuating all virtual machines and entering maintenance mode even though the host appears to be up and running.
Which new feature in vSphere 6.5 would cause this?

  • A. Predictive DRS
  • B. EVC Mode
  • C. vCenter HA
  • D. Proactive HA

Answer: D

Explanation: There are two vSphere Proactive HA Automation Levels:
Manual: vCenter Server will suggest only the migration recommendations for virtual machines. You need to manually migrate the virtual machines out from the degraded hosts.
Automated: Virtual Machines will be migrated to healthy hosts and degraded hosts will be entered into remediation action either quarantine or maintenance mode depending on the configured Proactive HA automation level

NEW QUESTION 12
Which system traffic type cannot be configured with Network I/O Control (NIOC) bandwidth allocation?

  • A. Virtual SAN traffic
  • B. ESXi host Management traffic
  • C. vSphere Replication traffic
  • D. Software FCoE Adapter traffic

Answer: D

Explanation: You can use NIOC to assign bandwidth for host management, virtual machines, iSCSI storage, NFS storage, vSphere vMotion, vSphere Fault Tolerance, vSAN, and vSphere Replication on the physical adapters that are connected to a vSphere Distributed Switch but not Fcoe Adapter traffic.

NEW QUESTION 13
An administrator has multiple vCenter Server 6.5 systems but cannot enable Storage I/O Control (SIOC) on a datastore shared by ESXi hosts managed by the vCenter Server systems.
Which action should the administrator take to resolve the issue?

  • A. Unmount the datastore and then enable SIOC on the vCenter Server system.
  • B. Configure the datastore to be managed by a single vCenter Server system.
  • C. Configure Storage DRS and then enable SIOC on the vCenter Server system.
  • D. Enable Raw Device Mapping (RDM) on the ESXi hosts.

Answer: B

Explanation: Before enabling SIOC, ensure that datastores are managed by a single vCenter Server.

NEW QUESTION 14
An administrator discovers that virtual machine migrations with encrypted vMotion have failed. Which action can resolve this issue?

  • A. Use vSphere Update Manager to upgrade all hosts to ESXi 6.5
  • B. Install a USB decryption dongle on all hosts in the cluster
  • C. Disable Strict Lockdown mode
  • D. Use esxcli to enable encrypted vMotion

Answer: A

NEW QUESTION 15
An administrator wants to enable VMware Fault Tolerance on a virtual machine. Which two vSphere features are supported with Fault Tolerance? (Choose two.)

  • A. VM Component Protection
  • B. vSphere HA
  • C. Storage DRS
  • D. Snapshots

Answer: BC

NEW QUESTION 16
An administrator wants to create and use a vApp.
Which pre-requisite must be met before the administrator can create a vApp?

  • A. The vApp can only be deployed in an EVC enabled cluster.
  • B. The vApp must be created within a StorageDRS cluster.
  • C. Non
  • D. vSphere 6.5 does not support vApp deployments.
  • E. The vApp can only be created in a DRS enabled cluster.

Answer: D

Explanation: You need to turn on Vsphere DRS to create vApp.

NEW QUESTION 17
Which two statements are true regarding Auto Deploy in version 6.5? (Choose two.)

  • A. Auto Deploy can be configured and managed via PowerCLI.
  • B. Auto Deploy can be configured and managed via the vSphere Client.
  • C. Auto Deploy can be configured and managed via the vSphere Web Client.
  • D. Auto Deploy can be configured and managed via vCLI commands.

Answer: AC

NEW QUESTION 18
Which is the correct sequence to upgrade a vSphere infrastructure?

  • A. vCenter Server > ESXi host > VMware Tools > VM compatibility
  • B. vCenter Server > ESXi host > VM compatibility > VMware Tools
  • C. ESXi host > vCenter Server > VMware Tools > VM compatibility
  • D. ESXi host > vCenter Server > VM compatibility > VMware Tools

Answer: A

NEW QUESTION 19
What are two reasons why a datastore in a Storage DRS cluster cannot enter maintenance mode? (Choose two.)

  • A. Storage latency is too high to allow Storage DRS initiate Storage vMotion.
  • B. Rules prevent Storage DRS from making migration recommendations.
  • C. Storage DRS is disabled on the virtual disk.
  • D. Storage DRS is configured for a VMFS3 datastore.

Answer: BC

Explanation: Problem
A datastore in a datastore cluster cannot either maintenance mode. The Entering Maintenance Mode status remains at 1%.
Cause
One or more disks on the datastore cannot be migrated with Storage vMotion. This condition can occur in the following instances.
Storage DRS is disabled on the disk
Storage DRS rules prevent Storage DRS from making migration recommendations for the disk.

Recommend!! Get the Full 2V0-622 dumps in VCE and PDF From Surepassexam, Welcome to Download: https://www.surepassexam.com/2V0-622-exam-dumps.html (New 276 Q&As Version)