getcertified4sure.com

DES-1D12 Exam

Top Quality EMC DES-1D12 Practice Online




We provide real DES-1D12 exam questions and answers braindumps in two formats. Download PDF & Practice Tests. Pass EMC DES-1D12 Exam quickly & easily. The DES-1D12 PDF type is available for reading and printing. You can print more and practice many times. With the help of our EMC DES-1D12 dumps pdf and vce product and material, you can easily pass the DES-1D12 exam.

Online DES-1D12 free questions and answers of New Version:

NEW QUESTION 1
When designing a Dell EMC SC Series system, which factors regarding general performance are important to understand?

  • A. Write size and latency
  • B. Block size and read size
  • C. Latency and queue depth
  • D. Transport and queue depth

Answer: C

Explanation:
"Whether gathering information or designing a system, it is important to understand two commonly used terms: Latency and queue depth"

NEW QUESTION 2
What is a characteristic of single-tier Flash on Dell EMC SC Series arrays?

  • A. Supports both write-intensive and read-intensive SSDs in the same tier
  • B. Snapshot data is kept on Tier1 in RAID 10 to optimize performance
  • C. Read only data is migrated to lower tiers when a snapshot is taken
  • D. Supports either write-intensive or read-intensive SSDs in the same tier

Answer: D

NEW QUESTION 3
Match each Dell EMC Unity feature with its destination.
DES-1D12 dumps exhibit


Solution:
DES-1D12 dumps exhibit

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 4
Which Dell EMC Unity feature provides network high availability with active-passive ports when provisioning File storage for a NAS client?

  • A. Redundant Interfaces
  • B. Preferred Interfaces
  • C. Link Aggregation
  • D. Fail-safe Networking

Answer: D

Explanation:
Document: docu71319_dell-emc-unity-high-availability-a-detailed-review.pdf
Page: 20 FAIL SAFE NETWORKING (FSN) Dell EMC Unity OE version 4.2.1 introduces Fail Safe Networking (FSN). FSN is a high availability feature that extends link failover into the network by providing switch-level redundancy. FSN appears as a single link with a single MAC address and potentially multiple IP addresses. FSN can consists of Ethernet ports, link aggregations, or any combination of the two. FSN adds an extra layer of availability to link aggregations alone as link aggregations provide availability in the event of a port failure while FSN provides availability in the event of a switch failure. Each port or Link aggregation is considered as a single connection and only the primary port or link aggregation in an FSN is active at a time. All ports in an FSN must have the same MTU size, but the speed and duplex settings can vary.

NEW QUESTION 5
What storage resources are affected with a refresh option on a Dell EMC PowerStore array?

  • A. Thin clones and volumes only
  • B. Snapshots, thin clones, and volumes
  • C. Thin clones, volumes, and replicas
  • D. Thin clones and snapshots only

Answer: A

NEW QUESTION 6
For Dell EMC SC Series arrays, what is the minimum percentage of total system IOPS that should be applied to Tier 3 drives?

  • A. 15%
  • B. 20%
  • C. 25%
  • D. 100%

Answer: B

Explanation:
"As a standard, tier 3 drives should encompass a minimum of 20% system IOPS potential."

NEW QUESTION 7
A customer has a Dell EMC SC9000 array with six SC420 enclosures running SCOS 7.3. The enclosure configuration is as follows:
DES-1D12 dumps exhibit Two enclosures have write-intensive SSDs
DES-1D12 dumps exhibit Four enclosures have read-intensive SSDs
What is recommended as a general guideline for making spare drive assignments?

  • A. 2 spare drives per shell
  • B. Dedicated spares are not required
  • C. 2 spares per drive type per array
  • D. 1 spare per drive type per shell

Answer: B

Explanation:
"SCOS 7.3, Distributed Sparing: eliminates the need for dedicated spares by giving customers the option to distribute sparing capacity across all drives in the array."

NEW QUESTION 8
What is a key feature of the Dell EMC Future-Proof Storage Loyalty Program for Dell EMC SC Series arrays?

  • A. 4:1 Performance Guarantee
  • B. 4 Year Satisfaction Guarantee
  • C. 4:1 Reduction Guarantee
  • D. 4:1 Efficiency Guarantee

Answer: D

Explanation:
Dell EMC Flash Storage Efficiency Guarantee Dell EMC promises our flash arrays will provide a logical usable capacity at least four times the usable physical capacity of your purchased drives —or we’ll give you more drives at no charge. https://www.delltechnologies.com/en-us/blog/dell-emc-flash-storage-efficiency/

NEW QUESTION 9
A customer site has four NAS servers participating in MetroSync replication. Which Dell EMC Unity feature could reduce failover times?

  • A. QoS Failover Policy
  • B. Cabinet Failover
  • C. SRDF Metro
  • D. Consistency Groups

Answer: B

NEW QUESTION 10
What component or feature is provided by both the Dell EMC PowerStore 1000T array and the Dell EMC Unity XT 380 Series array?

  • A. Container Integration
  • B. Configured Block with Hypervisor
  • C. Unified System
  • D. NVMe disks

Answer: C

Explanation:
"When positioning the 380 and 380F, keep in mind that they are not NVMe-ready and will not be upgradeable to support NMVe in the future.".

NEW QUESTION 11
Which features were introduced in SCOS 7.3?

  • A. Distributed Sparing and Live Volume ALUA
  • B. Data-in-Place upgrade for SC4020 and 4K HDD support
  • C. Unisphere for SC and Live Volume Auto-failover
  • D. CloudlQ support and Cross Platform Replication

Answer: A

Explanation:
https://dl.dell.com/topicspdf/sc-7-3_rn_en-us.pdf

NEW QUESTION 12
An ISP needs a data storage solution that allows them to set policies over resource usage. The solution needs to support network multi-tenancy while also providing full network failover protection.
What combination of Dell EMC SC Series features meets these requirements?

  • A. Thin Replication and Storage Profiles
  • B. VLAN Tagging and QoS
  • C. Multi-protocol and Live Volume
  • D. Replication and vVols

Answer: C

NEW QUESTION 13
How are vVol datastores mounted in Dell EMC PowerStore storage during the creation of vVol datastores in the vSphere environment shared by ESXi hosts?

  • A. Volume Groups
  • B. Storage containers
  • C. Storage Groups
  • D. VMFS datastores

Answer: B

Explanation:
A storage container is used to present vVol storage from a PowerStore cluster to vSphere. vSphere mounts the storage container as a vVol datastore and makes it available for VM storage. When a PowerStore cluster is used to provide VM storage, user VMs should be provisioned on the vVol datastores. The default storage container is mounted automatically on the nodes of the cluster.

NEW QUESTION 14
Which QoS options are supported by Dell EMC Unity XT?

  • A. VMFS Datastore and Storage Pool
  • B. iSCSI and Attached Snapshot
  • C. Individual LUN and iSCSI
  • D. Individual LUN and Group LUN

Answer: D

NEW QUESTION 15
How many hierarchical snapshots are supported by Dell EMC Unity?

  • A. 32 levels deep for LUNs16 levels deep for file systems
  • B. 16 levels deep for LUNs8 levels deep for file systems
  • C. 16 levels deep for LUNs16 levels deep for file systems
  • D. 10 levels deep for LUNs10 levels deep for file systems

Answer: D

Explanation:
https://elabnavigator.emc.com/vault/pdf/EMC_Unity_ESSM.pdf (pag.22)

NEW QUESTION 16
A Dell EMC Unity storage administrator needs to build a NAS server configuration to support failover between SPs and NAS resources. What is a term for this configuration?

  • A. Local Replication
  • B. IP Multi-tenancy
  • C. LACP
  • D. Separate IP Switches

Answer: A

NEW QUESTION 17
What provides data analytics for Dell EMC Midrange storage?

  • A. eLab Advisor
  • B. Unisphere Central
  • C. DSM
  • D. CloudIQ

Answer: D

NEW QUESTION 18
......

Recommend!! Get the Full DES-1D12 dumps in VCE and PDF From Downloadfreepdf.net, Welcome to Download: https://www.downloadfreepdf.net/DES-1D12-pdf-download.html (New 64 Q&As Version)