getcertified4sure.com

NS0-520 Exam

A Review Of Verified NS0-520 Exam Price




Our pass rate is high to 98.9% and the similarity percentage between our NS0-520 study guide and real exam is 90% based on our seven-year educating experience. Do you want achievements in the Network-Appliance NS0-520 exam in just one try? I am currently studying for the Network-Appliance NS0-520 exam. Latest Network-Appliance NS0-520 Test exam practice questions and answers, Try Network-Appliance NS0-520 Brain Dumps First.

Online NS0-520 free questions and answers of New Version:

NEW QUESTION 1

NS0-520 dumps exhibit
A customer is using both FC and NVMe in a cluster. The customer needs to do some work on AFF_1. Referring to the exhibit, what will happen?

  • A. The NVMe namespaces on AFF_2 will be available after takeover of AFF_1.
  • B. The FC LUNs that use cluster interconnect to access the LUNs on AFF_1 will be unavailable after failover.
  • C. The FC LUNs on node AFF_2 will be unavailable after failover of AFF_1.
  • D. The NVMe namespaces on AFF_1 will be unavailable after takeover by AFF_2.

Answer: C

NEW QUESTION 2

You want to move a SAN LIF and preserve its configuration information and avoid rezoning the switch fabric. In this scenario, which two steps must be performed to fulfill this goal? (Choose two)

  • A. Move the SAN LIF to another node in a cluster on a different storage virtual machine (SVMs)
  • B. Keep the SAN LIF online before it is moved
  • C. Take the SAN LIF offline before it is moved
  • D. Move the SAN LIF to another node in a cluster on existing storage virtual machine (SVMs)

Answer: CD

Explanation:
Moving SAN LIFs
If a node needs to be taken offline, you can move a SAN LIF to preserve its configuration information, such as its WWPN, and avoid rezoning the switch fabric. Because a SAN LIF must be taken offline
before it is moved, host traffic must rely on host multipathing software to provide nondisruptive access to the LUN. You can move SAN LIFs to any node in a cluster, but you cannot move the SAN LIFs
between storage virtual machines (SVMs). Yoy can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-09F5C2A3-FA6

NEW QUESTION 3

You want to ensure maximum performance of iSCSI LUNs on an AFF A220. In this scenario, which two actions will accomplish this task? (Choose two.)

  • A. Disable flow control.
  • B. Configure virtual LAN (VLAN).
  • C. Enable flow control.
  • D. Enable jumbo frames.

Answer: CD

NEW QUESTION 4

You have finished deploying a Netapp AFF All SAN Array Cluster and want to test the persistent ports feature. In this scenario, how would you accomplish this task?

  • A. Perform a takeover of a node
  • B. Disconnect an FCP initiator port
  • C. Disconnect an FCP target port
  • D. Disable a SAN LIF

Answer: A

Explanation:
If we don't have OnCommand Insight, then we should not pull out a cable as test because it won't be detected properly.
Doing a planned takeover will meet the requirements asked. Table Description automatically generated
NS0-520 dumps exhibit
You can find more information on this link: https://www.netapp.com/pdf.html?item=/media/10379-tr4515.pdf&v=20217121554 (26)

NEW QUESTION 5

A customer is expanding an ONTAP 9.4 switchless 2-node FAS2750 cluster. Two AFF A220 nodes will be added to the cluster.
In addition to the cluster nodes, what else is required to perform the cluster expansion?

  • A. Additional management switches are required.
  • B. An upgrade to ONTAP 9.5 is required.
  • C. Cluster switches are required.
  • D. Additional DS224C shelves are needed.

Answer: A

NEW QUESTION 6

Which two features does Assymmetric Namespase Access (ANA) support? (Choose two.)

  • A. multipathing
  • B. LUN masking
  • C. LUN hosting
  • D. path management

Answer: AD

NEW QUESTION 7

Exhibit.
NS0-520 dumps exhibit
You are working on a project to install a new AFF A300 storage array. You use a pair of Nexus 3596 switches for FC connectivity between your VMware ESXi servers and the AFF A300.
Which SAN switch feature must be enabled to accomplish this task?

  • A. N_Port ID visualization (NP1V)
  • B. Open Shortest Path First (OSPF)
  • C. Link Aggregation Control Protocol (LACP)
  • D. N_Port Visualization (NPV)

Answer: A

NEW QUESTION 8

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, which two statements are true? (Choose two.)

  • A. The volume guarantee has no effect.
  • B. LUN overwrites are guaranteed.
  • C. The LUN might run out of space.
  • D. The LUN space reservation has no effect.

Answer: BC

NEW QUESTION 9

You are installing a NetApp FAS6040 high availability storage system. Which cfmode should be set to ensure proper failover in an HP-UX environment?

  • A. standby
  • B. partner
  • C. single system image
  • D. dual_fabric

Answer: C

NEW QUESTION 10

Which option needs to be set on a volume to guarantee that it cannot be affected by other volumes?

  • A. None
  • B. Volume
  • C. Space Reserved
  • D. Reservation Enabled

Answer: B

NEW QUESTION 11

Exhibit.
NS0-520 dumps exhibit
The exhibit shows the Inn show command output for the oradata oraFinProd_l LUN. Which two statements ate correct about the LUN'? (Choose two.)

  • A. The LUN Is thick provisioned.
  • B. The LUN supports SCSI Tin unmap.
  • C. The LUN type is Windows.
  • D. The LUN is thin provisioned.

Answer: BD

NEW QUESTION 12

You have an existing 8-node Netapp Cluster serving NFS data, and you want to expand your cluster by an additional four nodes to serve ISCSI. In this scenario, where would you validate this configuration?

  • A. Active IQ Upgrade Advisor
  • B. Interoperability Matrix Tool
  • C. SAN Administration Guide
  • D. Hardware Universe

Answer: D

Explanation:
Hardware Universe shows how many nodes and which filers are compatible to mix between them

NEW QUESTION 13

A customer is planning to connect a Linux server to a FAS8200 using Brocade FC switches. During the initial configuration, the SVM does not log in to the fabric.
Which two statements are correct in this scenario? (Choose two.)

  • A. NPIV has not been enabled on the switches.
  • B. The switch port topology is set incorrectly to the E_Port.
  • C. ALUA has not been set up on the FAS8200.
  • D. Zoning is incorrectly configured between the Linux server and the ONTAP cluster.

Answer: AC

NEW QUESTION 14

You are booting a NetApp storage system for the first time. In which order should the various components be powered on?

  • A. any tape backup devices, disk shelves, network switches, NetApp controller heads
  • B. NetApp controller heads, disk shelves, any tape backup devices, network switches
  • C. NetApp controller heads, disk shelves, network switches, any tape backup devices
  • D. network switches, disk shelves, any tape backup devices, NetApp controller heads

Answer: D

NEW QUESTION 15

You are configuring both NVMe and FC on the same AFF A800 2-node ONTAP 9.5 cluster. You are configuring both protocols on the same Cisco FC network switches.
In this scenario, which configuration on the cluster is supported?

  • A. a volume with both LUNs and namespaces
  • B. an SVM with both nvme and fcp allowed protocols
  • C. an AFF A800 node HBA with both NVMe/FC and FC on the same port
  • D. a LIF with both fc-nvme and fcp data protocols

Answer: A

NEW QUESTION 16

An administrator needs to determine the maximum volume size that is supported per operating system. Which resource has this information?

  • A. Config Advisor
  • B. OneCollect
  • C. Interoperability Matrix Tool (IMT)
  • D. Hardware Universe (HWU)

Answer: C

NEW QUESTION 17

In an NVMe/FC environment, the host cannot discover the namespace on the AFF system. Referring to the exhibit, what is the problem?
NS0-520 dumps exhibit

  • A. The host MPIO drivers are not installed
  • B. NVMe is not supported on the FC adapter
  • C. The NQN is not correct
  • D. The NVMe service is not running on the SVM

Answer: C

Explanation:
We would not be able to run that command if NVMe is not enabled NVMe is supported on the same SVM along with FC protocol
The multipath tool on NVMe is called ANA
NQN needs to be correctly declared on the subsystem to map the new NVMe resources

NEW QUESTION 18

You created a LUN in a new volume on your Netapp ONTAP cluster. You enabled the default snapshot schedule and enabled snapshot autodelete on the volume. In this scenario, in which three situations
does the snapshot autodelete feature automatically delete snapshot copies in the volume? (choose three)

  • A. The snapshot reserve space is nearly full
  • B. The LUN is nearly full
  • C. The overwrite reserve space is full
  • D. The volume is nearly full
  • E. The aggregate is nearly full

Answer: ACD

Explanation:
Depending on what is selected in the "Trigger" option, Snapshot Autodelete will automatically delete a snapshot when, either the volume space utilized, or the snapshot reserve reaches a threshold capacity
specified below.
Automatic deletion of Snapshot copies from flexible volumes Data ONTAP can automatically delete one or more Snapshot copies on the volume, provided the Data ONTAP Snapshot copy autodeletion
policy is enabled and set to trigger when the overwrite reserve is nearly full on the volume. You can find more information on this link:
https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/How_to_use_Snapsh
https://library.netapp.com/ecmdocs/ECMP1217281/html/GUID-98FB8EC4-F3AE-4D25-AF44-E3200AFEB1A

NEW QUESTION 19

A4-node ONTAP FAS9000 cluster was used to serve I/O from six RedHat 7.3 servers. The servers were configured with maximum, queue depth.
For production purposes, an additional 60 similarly configured hosts were added to the environment. Later, the hosts started reporting random QFull errors, and the aggregated performance degraded.
Which two solutions would alleviate the QFull errors and performance problems? (Choose two.)

  • A. Remove Selective LUN Mapping (SIM) from the 4-node FAS9000 cluster.
  • B. Download the latest FC HBA driver, firmware, and BIOS, and deploy them on the hosts.
  • C. Configure and use additional FC target HBAs in the FAS9000 cluster.
  • D. Reduce FC HBA gueue depth on the hosts.

Answer: CD

NEW QUESTION 20
......

P.S. Easily pass NS0-520 Exam with 234 Q&As Surepassexam Dumps & pdf Version, Welcome to Download the Newest Surepassexam NS0-520 Dumps: https://www.surepassexam.com/NS0-520-exam-dumps.html (234 New Questions)